Alesis HR-16:B Manuel d'utilisateur Page 27

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 72
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 26
The MIDI CLOCK OUT function Is used to turn on or off the transmission of MIDI
clocks. The display is as follows:
MIDI CLOCK OUT
08 MIDI CLOCK
OUT ENABLE: ON
The +/- arrow buttons are used to turn this function on or off. The default Is ON.
AUTO START
The AUTO START function Is used to turn on or off the capability of starting a
pattern or song automatically if a MIDI start or tape sync signal occurs. The
display is as follows:
09 AUTO START
ENABLE: QN
The +/- arrow buttons are used to turn this function on or oft. The default is ON.
The HR-16 does not need to turn on or off its internal clock, since it intelligently
determines what clock to use when necessary. A functional description of the
clocking possibilities are shown in the table below:
CUXK
SOURCE
AUTO
START
PRESS
PLAY
RECEIVE
MIDI START
RECEIN
TAPE!
MIDI & INTERNAL OFF 2 6 1
MIDI & INTERNAL CN 2 6 1
INTERNAL ONLY OFF 2 1 1
INTERNAL ONLY CN 2 2 1
TAPESYNC
OFF
3 1
4
TAPESYNC CN 3 1 5
1. Do nothing.
2. Start playing from beginning with internal clock.
3. Enter play mode, but don't start playing until tape sync clock occurs.
4. If in play mode, start playing, otherwise ignore sync.
5. Start playing from beginning with tape sync clock.
6 Start playing from beginning with MIDI clock.
If tape sync and auto start are on and a pattern or song is playing, it will stop
playing automatically if the tape sync signal is interrupted for more than 1
second. If auto start is not on, the HR-16 will wait in play for more sync pulses.
Alesis HR-16 Instructions ..................................................................................................................................... Page 21
Vue de la page 26
1 2 ... 22 23 24 25 26 27 28 29 30 31 32 ... 71 72

Commentaires sur ces manuels

Pas de commentaire